Reproductibilité de la mesure de la force et de l’endurance du quadriceps dans la BPCO - 29/11/17

Doi : 10.1016/j.rmr.2016.11.004 
M. Beaumont a, , b , G. Kerautret c, L. Peran a, R. Pichon a, C. Le Ber a, M. Cabillic c, d
a Service de réhabilitation respiratoire, centre hospitalier des Pays-de-Morlaix, Kersaint Gilly, BP 97237, 29672 Morlaix cedex, France 
b Unité de recherche EA3878 (groupe d’étude de la thrombose de Bretagne-Occidentale), CHU de Brest, 29200 Brest, France 
c Institut régional de formations aux métiers de la rééducation et de la réadaptation des Pays-de-la-Loire, 54, rue de la Baugerie, 44230 Saint-Sébastien-sur-Loire, France 
d Institut de formation en masso-kinésithérapie, 12, rue Jean-Louis-Bertrand, 35000 Rennes, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

Les patients atteints de BPCO ont fréquemment une altération de la force et de l’endurance des membres inférieurs et l’évaluation des quadriceps est recommandée dans cette pathologie. Le dynamomètre manuel est un instrument facile d’utilisation pour cette évaluation ; toutefois, la reproductibilité de ses mesures n’a pas été étudiée pour l’endurance. L’objectif de cette étude était d’évaluer la reproductibilité inter et intra-opérateur des mesures de force maximale volontaire et d’endurance des quadriceps avec un dynamomètre manuel chez des patients atteints de BPCO.

Méthode

Les mesures de force maximale volontaire et d’endurance du quadriceps ont été effectuées en isométrique à l’aide d’un même dynamomètre manuel. Trois sessions de mesures séparées de 24 heures chacune ont été réalisées. Les reproductibilités intra- et interopérateurs ont été évaluées par le calcul du coefficient de corrélation intraclasse.

Résultats

Vingt et un patients ont été inclus. Les coefficients de corrélations intraclasses pour la force maximale volontaire en intra- et interopérateurs étaient compris entre 0,95 et 0,99. Concernant l’endurance, le coefficient pour la reproductibilité intra-opérateur était de 0,81. Les deux coefficients de corrélation intraclasse pour la reproductibilité interopérateurs étaient de 0,69 et 0,77.

Conclusion

Le dynamomètre permet une excellente reproductibilité de la force maximale volontaire et une reproductibilité correcte à excellente de l’endurance. Cet outil est utilisable pour l’évaluation en pratique courante du quadriceps dans la BPCO, en particulier au cours de la réhabilitation respiratoire.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

Patients with COPD frequently have lower strength and endurance in their lower limbs compared to healthy subjects and evaluation of their quadriceps strength is recommended in practice. The handheld dynamometer has been validated and is easy to use for this measurement but its reproducibility has never been studied for endurance evaluation and only poorly for strength. The objective of this study was to estimate the inter and intra-operator reproducibility of maximal voluntary strength and endurance measurements of the quadriceps with a handheld dynamometer in patients with COPD.

Methods

The measurements of maximal voluntary strength and endurance were performed with a single handheld dynamometer using isometric contraction. Three measurement sessions were undertaken, separated by 24hours. The intra- and interoperator reproducibility were estimated by calculation of the intraclass correlation coefficient.

Results

Overall, 21 patients were included in the study. The intraclass correlation coefficient calculated for the maximal voluntary strength for intra and interoperator reliability ranged between 0.95 and 0.99. For endurance, the coefficient for intra-operator reliability was 0.81 and the two for interoperator reliability were 0.69 and 0.77.

Conclusion

The handheld dynamometer allows an excellent inter and intra-operator reproducibility for the measurement of quadricipital maximal voluntary strength and a correct to excellent reproducibility for the measurement of quadricipital endurance. This tool may be used for the evaluation of quadriceps strength in clinical practice in COPD patients, particularly during rehabilitation.

Le texte complet de cet article est disponible en PDF.

Mots clés : Évaluation musculaire, Dynamomètre manuel, BPCO, Quadriceps

Keywords : Muscular evaluation, Handheld dynamometer, COPD, Quadriceps muscle


Plan


© 2017  SPLF. Publié par Elsevier Masson SAS. Tous droits réservés.
Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 9

P. 1000-1006 - novembre 2017 Retour au numéro
Article précédent Article précédent
  • Stratégies thérapeutiques les 2 premières années après un diagnostic de cancer du poumon. ESCAP-2011-CPHG, étude en situation réelle réalisée dans les hôpitaux généraux français
  • M. Grivaux, F. Goupil, B. Asselain, F. Blanchon, T. Collon, D. Coëtmeur, C. Dayen, C. Locher, O. Molinier, F. Martin, D. Debieuvre
| Article suivant Article suivant
  • Un cas atypique de pneumopathie nécrosante staphylococcique !
  • E. Bertreau, S. Grard, T. Baudry, N. Freymond