S'abonner

Ultrasonographic anatomy of the long thoracic nerve: A reappraisal using high frequency (24-MHz) probe - 31/03/21

Doi : 10.1016/j.diii.2020.08.003 
M. Faruch Bilfeld a, , F. Lapègue a, P. Cintas b, B. Acket b, H. Basselerie a, R. Bachour a, F. Nougarolis a, C. Ricard a, H. Chiavassa Gandois a, P. Laumonerie c, C. Aprodoaei c, N. Sans a
a Department of Radiology, CHU Toulouse-Purpan, 31059 Toulouse cedex 9, France 
b Department of Neurology, CHU Toulouse-Purpan, place du Docteur Baylac, 31059 Toulouse cedex 9, France 
c Department of Orthopedic Surgery, CHU Toulouse-Purpan, place du Docteur Baylac, 31059 Toulouse cedex 9, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

The long thoracic nerve can be examined with ultrasound above the clavicle and along the chest wall.
Ultrasound is a highly reproducible technique to investigate the long thoracic nerve.
In patients with winged scapula, ultrasound study of the long thoracic nerve may contribute to select treatment option.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The purpose of this study was to analyze the potential of ultrasound with a high frequency probe (24-MHz) in the assessment of the long thoracic nerve (LTN) and describe ultrasonographic landmarks that can be used for standardization.

Material and methods

Ultrasonography analysis of the LTN was done on 2 LTNs in a cadaver specimen and then on 30 LTNs in 15 healthy volunteers (12 men, 3 women; mean age, 28.8±3.8 [SD] years; age range: 24–39 years) by two independent radiologists (R1 and R2) using a 24-MHz probe. Interrater agreement was assessed using Kappa test (K) and intraclass correlation coefficient (ICC).

Results

In the cadaver, dissection confirmed that the India ink was injected near the LTN in the middle scalene muscle. In volunteers, visibility of the LTN above the clavicle was highly reproducible for the branches arising from C5 (R1: 87% [26/30]; R2: 90% [27/30]; K=0.83) and from C6 (R1: 100% [30/30]; R2: 97% [29/30]; K=0.94). Where the nerve emerged from the middle scalene muscle, the mean diameter was 0.85±0.24 (SD) mm (range: 0.4–1.6mm) for R1 and 0.9±0.23 (SD) mm (range: 0.4–1.7mm) for R2 (ICC: 0.96; 95% CI: 0.92–0.98%). Along the thoracic wall, where LTN run along the lateral thoracic artery, the mean diameter was 0.83±0.19 (SD) mm (range: 0.5–1.27mm) for R1 and 0.89±0.21 (SD) mm (range: 0.6–1.2mm) for R2 (ICC: 0.86; 95% CI: 0.72–0.93%).

Conclusion

The LTN can be analyzed with ultrasound using high-frequency probe by using the C5 and C6 roots, the middle scalene muscle above the clavicle and the lateral thoracic artery on the chest wall as landmarks.

Le texte complet de cet article est disponible en PDF.

Keywords : Ultrasonography, Anatomy, Thoracic nerve, High-resolution ultrasound

Abbreviations : BMI, ICC, LTN, MRI


Plan


© 2020  Publié par Elsevier Masson SAS.
Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 4

P. 241-245 - avril 2021 Retour au numéro
Article précédent Article précédent
  • Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography
  • Pierre-Alexis Autrusseau, Aïssam Labani, Pierre De Marini, Pierre Leyendecker, Cédric Hintzpeter, Anne-Claire Ortlieb, Michael Calhoun, Ilya Goldberg, Catherine Roy, Mickael Ohana
| Article suivant Article suivant
  • Non-invasive diagnosis of severe alcoholic hepatitis: Usefulness of cross-sectional imaging
  • F. Grillet, P. Calame, J.-P. Cervoni, D. Weil, T. Thevenot, M. Ronot, E. Delabrousse