S'abonner

Low-frequency Intrapulmonary Percussive Ventilation Increases Aerosol Penetration in a 2-Compartment Physical Model of Fibrotic Lung Disease - 09/06/21

Doi : 10.1016/j.rmr.2021.02.055 
S. Le Guellec 1, 2, L. Allimonnier 1, , N. Heuzé-Vourc’h 1, 3, M. Cabrera 1, F. Ossant 4, J. Pourchez 5, L. Vecellio 1, 3, L. Plantier 1, 3, 6
1 Inserm U1100, Research Center for Respiratory Diseases, Tours, France 
2 DTF Medical, DTF Aerodrug 
3 Université de Tours, Tours, France 
4 Inserm U1253, Imagerie et Cerveau, Tours, France 
5 Mines Saint-Etienne, Université Lyon, Université Jean Monnet, Inserm, U 1059 Sainbiose, Centre CIS, Saint-Etienne, France 
6 CHRU de Tours, Service de Pneumologie et Explorations Fonctionnelles Respiratoires, Tours, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction

In patients with fibrotic pulmonary disease such as idiopathic pulmonary fibrosis (IPF), inhaled aerosols deposit mostly in the les affected region of the lung, resulting in suboptimal pharmacokinetics of airway-delivered treatments. Refinement of aerosol delivery technique requires new models to simulate the major alterations of lung physiology associated with IPF, i.e. heterogeneously reduced lung compliance and increased airway caliber.

Methods

A novel physical model of the respiratory system was constructed to simulate aerosol drug delivery in spontaneously breathing (negative pressure ventilation) IPF patients. The model comprises upper (Alberta idealized throat) and lower airway (plastic tubing) models and branches into two compartments (Michigan lung model) which differ in compliance and caliber of conducting airway. Aerosol penetration and deposition (using NaF as a model aerosol) in the model was studied in different conditions.

Results

The model was able to reproduce the heterogeneous, compliance-dependent reduction in ventilation and aerosol penetration seen in the fibrotic lung regions in IPF. Addition of intrapulmonary percussive ventilation (IPV) induces a 2-3 fold increase in aerosol penetration in the low-complaince/high airway caliber compartment of the model, demonstrating the responsiveness of the model to therapeutic intervention.

Conclusion

Thanks to the model, we observed that reduced compliance of target lung regions is a critical determinant of aerosol penetration, and thus presumably of aerosol deposition. This finding underscores the need for techniques specifically tailored to enhance delivery of inhaled aerosols to low compliance regions of lungs. Low-frequency IPV (≤3Hz) pulses may represent an attractive option to increase aerosol deposition in fibrotic lung regions.

Le texte complet de cet article est disponible en PDF.

Keywords : Physiologie, Contrôle ventilatoire


Plan


© 2021  Publié par Elsevier Masson SAS.
Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 38 - N° 6

P. 594-595 - juin 2021 Retour au numéro
Article précédent Article précédent
  • Le deep breathing montre une dysfonction autonomique chez des sujets avec syndrome d’apnées obstructive du sommeil
  • M. Onanga, S. Joanny, J.B. Maranci, T. Similowski, I. Arnulf, C. Sevoz-Couche, S. Redolfi
| Article suivant Article suivant
  • Monitoring de la santé respiratoire par analyse de la variabilité et analyse fréquentielle du mouvement thoracique
  • C. Boichat, M. Graverot, T. Lebrun, U. Kindler, F. Kindler