S'abonner

Comparaison de l’aérosol de la cigarette électronique à celui des cigarettes ordinaires et de la chicha - 22/11/13

Doi : 10.1016/j.rmr.2013.03.003 
J.-F. Bertholon a, b, , M.H. Becquemin a, c, M. Roy a, F. Roy d, D. Ledur e, I. Annesi Maesano f, B. Dautzenberg b, g
a Service d’explorations fonctionnelles de la respiration, de l’exercice et de la dyspnée, laboratoire de granulométrie et de dépôt des aérosols, groupe hospitalier Pitié-Salpêtrière, Assistance publique–Hôpitaux de Paris, 47-83, boulevard de l’Hôpital, 75013 Paris, France 
b Faculté de médecine, université Pierre- et Marie-Curie (UPMC), 27, rue de Chaligny, 75012 Paris, France 
c Université Paris Diderot, Sorbonne Paris Cité, ER 10 UPMC, 5, rue Thomas-Mann, 75013 Paris, France 
d SureDyna, 7, rue Sylvine Candas, 92120 Montrouge, France 
e Société Ecomesure, 3, rue du Grand-Cedre, 91640 Janvry, France 
f EPAR, UMR-S707 Inserm, 27, rue de Chaligny, 75012 Paris, France 
g Service de pneumologie, groupe hospitalier Pitié-Salpêtrière, Assistance publique–Hôpitaux de Paris, 47-83, boulevard de l’Hôpital, 75013 Paris, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

L’étude expérimentale d’une cigarette électronique avec haute teneur en nicotine ou sans nicotine, a été réalisée sur l’aérosol liquide qu’elle produit lors de l’inhalation du fumeur. Les tailles des gouttelettes de cet aérosol ont été mesurées à l’aide d’un impacteur électrostatique à basse pression, ELPI, permettant d’établir une distribution des tailles en temps réel, de calculer la taille médiane, D50, et la dispersion, σg des gouttelettes. Les valeurs de D50 obtenues pour le courant principal C1, inhalé par le fumeur, étaient de 0,65μm et 0,60μm, avec et sans nicotine. Les probabilités de dépôt dans les voies respiratoires étaient donc d’environ 26 % pour le dépôt total et de 14 % dans les alvéoles. Pour le courant C3, expiré par le fumeur dans son environnement, le D50 était de 0,34μm et 0,29μm avec et sans nicotine. La demi-vie dans l’air du courant principal C1 était de 11 secondes car il disparaît en s’évaporant rapidement passant sous forme gazeuse. Par comparaison avec les cigarettes ordinaires et la chicha qui produisent un aérosol dont les particules ont une demi-vie de 19 à 20minutes, il ne présente pas de risque réel de « tabagisme passif ».

Le texte complet de cet article est disponible en PDF.

Summary

In previous studies of the smoke from regular cigarettes and water pipes, we measured aerosol particle sizes in three streams; S1, inhaled by the smoker, S2, released by the device itself and S3, exhaled by the smoker. We used an electrostatic low-pressure impactor (ELPI), giving particle size distributions in real time and calculated median diameters, D50, and dispersion (σg). This allowed us to predict airway deposition. In addition, the aerosol particle half-life in the air was used as a measure of the risk to others from passive smoking. With the same equipment, we measured the particle sizes and persistence in air of the liquid aerosol generated by e-cigarettes (Cigarettec®) containing water, propyleneglycol and flavorings with or without nicotine. Aerosol generation was triggered by a syringe or by the inspiration of volunteer smokers. The D50 data obtained in S1, were 0.65μm with nicotine and 0.60μm without nicotine. Deposition in the airways could then be calculated: 26% of the total would deposit, of which 14% would reach the alveoli. These data are close to those found with regular cigarettes. For S3, D50 data were 0.34μm and 0.29μm with or without nicotine. The half-life in air of the S3 stream was 11seconds due to a rapid evaporation. The-e-cigarette aerosol, as measured here, is made of particles bigger than those of cigarette and water pipe aerosols. Their deposition in the lung depends on their fate in the airways, which is unknown. Contrary to tobacco smoke, which has a half-life in air of 19 to 20minutes, the risk of passive “smoking” exposure from e-cigarettes is modest.

Le texte complet de cet article est disponible en PDF.

Mots clés : E-cigarette, Nicotine, Aérosol, Tabagisme passif, Tailles particulaires

Keywords : Electronic cigarette, Nicotine, Aerosol, Passive smoking, Particle sizes


Plan


© 2013  SPLF. Publié par Elsevier Masson SAS. Tous droits réservés.
Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 9

P. 752-757 - novembre 2013 Retour au numéro
Article précédent Article précédent
  • Couverture vaccinale grippale et pneumococcique dans un SSR de pneumologie
  • F. Vandenbos, J. Gal, B. Radicchi
| Article suivant Article suivant
  • Performance diagnostique de l’EBUS-PTBA chez des patients aux antécédents néoplasiques extrapulmonaires adressés pour adénopathies médiastinales
  • G. Tercé, X. Dhalluin, C. Delattre, B. Bouchindhomme, M.-C. Copin, P.-P. Ramon, C. Fournier